珠海一号高光谱卫星辐射精度真实性检验研究
作者:
作者单位:

北华航天工业学院 廊坊 065000

作者简介:

刘 宁 1998年生,硕士研究生,主要研究方向为遥感产品真实性检验。
刘其悦 1985年生,博士,讲师,主要研究方向为辐射定标和遥感产品真实性检验。
朱 霞 1989年生,博士,讲师,主要研究方向为地理时空数据挖掘与分析。
张文豪 1986年生,博士,副教授,主要研究方向为大气遥感。
金永涛 1977年生,博士,教授,主要研究方向为遥感技术与应用和计算机网络与信息安全。
郭子阳 1998年生,硕士研究生,主要研究方向为辐射定标。

通讯作者:

中图分类号:

TP212.14;TP202+.2

基金项目:

国家重点研发计划项目(2019YFE0127300);河北省全职引进高端人才科研项目(2020HBQZYC002);北华航天工业学院博士基金项目(BKY-2022-13,BKY-2021-30);河北省自然科学基金(D2020409003);国防基础科研项目(JCKY2020908B001,JCKY2019407D004);高分辨率对地观测系统重大专项(30-Y30F06-9003-20/22);廊坊市科技局(2021011078);国家科技重大专项(67-Y50G04-9001-22/23)


Research on the validation of radiometric accuracy of ZhuHai-1 hyperspectral satellite
Author:
Affiliation:

North China Institute of Aerospace Engineering, Langfang 065000, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    “珠海一号(OHS)”高光谱商业遥感卫星数据在国民经济建设中发挥着越来越重要的作用。当前,针对商业遥感卫星数据质量精度的验证和评价研究成果较少。本文基于地面实测数据,对OHS卫星高光谱数据的辐射精度进行了真实性检验和定量分析。结果表明:OHS卫星表观辐亮度与实测结果具有较好的线性相关关系,相关系数R2大于0.7。与实测结果相比,OHS卫星各通道表观辐亮度值整体偏低,但两者光谱曲线形态基本一致。随着时间的推移,OHS传感器性能可能存在衰减,不同通道的衰减程度不一;在31个通道中,与实测值之间的相对差异在20%以内的通道数为9个;在20%~30%之间为14个,30%~40%为8个。

    Abstract:

    ZhuHai-1 (OHS) hyperspectral commercial remote sensing satellite data is playing an increasingly important role in national economic construction. At present, there are few research results on the verification and evaluation of the quality and accuracy of commercial remote sensing satellite data. In this paper, based on the measured data on the ground, the radiation accuracy of OHS satellite hyperspectral data is tested and quantitatively analyzed. The results show that: firstly, the apparent radiance of OHS satellite has a good linear correlation with the measured results, and the correlation coefficient R2 is greater than 0.7. Secondly, compared with the measured results, the apparent radiance of each channel of OHS satellite is generally low, but the spectral curve shape of both channels is basically consistent. Thirdly, as time goes on, the performance of OHS sensor may be attenuated, and the attenuation degree of different channels is different. Among the 31 channels, the number of channels whose relative difference with the measured value is within 20% is 9. There are 14 in 20% - 30% and 8 in 30% - 40%.

    相似文献
    引证文献
引用本文

刘宁,刘其悦,朱霞,张文豪,金永涛,郭子阳.珠海一号高光谱卫星辐射精度真实性检验研究[J].遥测遥控,2023,44(3):98-106.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
    参考文献
历史
  • 收稿日期:2022-11-08
  • 最后修改日期:2022-11-25
  • 录用日期:
  • 在线发布日期: 2023-05-15
  • 出版日期:
  • 优先出版日期: 2023-05-15